EN 55015:2006 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
Scope
International standard EN 55015:2006 is applicable to:
- all lighting equipment intended to be used for light generation and illumination purposes and intended to be used with batteries or connected to low voltage mains network;
- lighting part of installation or multifunctional equipment if one of the main purposes of usage is illumination;
- accessories that are usable only with lighting equipment;
- IR and UV radiation equipment;
- scoreboards, advertising signs;
- lighting equipment intended to be used outdoors;
- lighting equipment intended to be used in busses and trains;
Classification
International standard EN 55015:2006 have no classification of equipment it covers.
Examples
Luminaries, street LED lighting devices, table lamps, office lighting equipment.
Requirements
Insertion loss requirements must be met in frequency range 150kHz-1.605MHz (limited applicability).
Conducted emission requirements for mains ports must be met in frequency range 9kHz-30MHz.
Conducted emission requirements for load terminals and control terminals must be met in frequency range 150kHz-30MHz.
Radiated emission requirements must be met in frequency rage 9kHz-300MHz.
Standard EN 55015 :2006 limit line for conducted emissions on mains ports
Standard EN 55015 :2006 limit line for radiated emissions
Standard EN 55015 :2006 limit line for radiated emissions